Studi Kasus Repeat (Pengulangan) Radiograf dengan Modalitas Digital Radiography (DR) di Instalasi Radiologi RSUD Dr. Soehadi Prijonegoro Sragen
DOI:
https://doi.org/10.55606/klinik.v4i2.3929Keywords:
Repeat, Radiograph, Digital RadiographyAbstract
Repeat analysis is a systematic method for analyzing radiographic images repeatedly to identify and reduce errors in digital processing. This method is part of the quality assurance (QA) and quality control (QC) program which aims to ensure optimal quality radiographic results. According to the Decree of the Minister of Health Number 129/Menkes/SK/II/2008 concerning the standard for repeat radiographic images <2%. This study aims to determine the factors that cause repeat photos and how to prevent repeat photos at Dr. Soehadi Prijonegoro Sragen Hospital. This research method uses qualitative with a case study approach to analyze repeat radiographs using Digital Radiography (DR) at the Radiology Installation of Dr. Soehadi Prijonegoro Sragen Hospital. The study was conducted from September 2024 to March 2025. The population includes all radiographic images with DR modality, while the sample is the result of repeat radiographic images. Data were collected through direct observation, interviews with three radiographers and one radiology specialist, and documentation. The average percentage of repeat X-ray photos on digital radiography modality in October 2024 was 1954 examinations with 122 repeats with a percentage of 6.24%, in November 2024 was 2206 examinations with 70 repeats with a percentage of 3.17%, in December 2024 was 2622 examinations with 16 repeats with a percentage of 0.61%. The percentage of repeats on digital radiography (DR) modality that occurred at Dr. Soehadi Prijonegoro Sragen Hospital exceeded the standards set by the Minister of Health with repeat results> 2% in October and November 2024. The factors causing repeats are due to positioning, patient movement, exposure factors, artifacts and equipment. The suggestion to minimize repeats that occur is to increase the accuracy of the radiographer in conducting the examination.
References
Anif Chafidhi, N., & Suraningsih, T. B. (2019). Analisis pengulangan citra digital dengan menggunakan digital radiography di instalasi radiologi Rumah Sakit Panti Waluyo Surakarta. Jurnal Pijar MIPA, 14(1), 1–12.
Artitin, C.-. (2022). Analisa pengulangan (repeat) radiograf di unit radiologi Rumah Sakit Umum Daerah Mohammad Natsir Solok. Jurnal Teras Kesehatan, 5(1), 25–30. https://doi.org/10.38215/jtkes.v5i1.72
Dwi Lestari, & Fatimah. (2019). [Judul artikel tidak lengkap]. Jurnal Radiografer Indonesia, 2620-9950, 106–110.
Fajarrissetyo, I. J., Nurcahyo, P. W., & Aryani, A. I. (2015). Analisis penolakan dan pengulangan citra radiografi pada modalitas computed radiography AGFA CR 35-X di instalasi radiologi RSUD Dr. R. Goeteng Taroenadibrata Purbalingga. Jurnal Imejing Diagnostik (JImeD), 1(2), 78–81. https://doi.org/10.31983/jimed.v1i2.3159
John, P., & Lampignano, L. E. K. (n.d.). Bontrager’s textbook of radiographic positioning and related anatomy (9th ed.).
Kazerooni, E. A., Austin, J. H. M., Black, W. C., Dyer, D. S., Hazelton, T. R., Leung, A. N., McNitt-Gray, M. F., Munden, R. F., & Pipavath, S. (2014). ACR-STR practice parameter for the performance and reporting of lung cancer screening thoracic computed tomography (CT): 2014 (Resolution 4). Journal of Thoracic Imaging, 29(5), 310–316. https://doi.org/10.1097/RTI.0000000000000097
Mareta, S., Sari, O. P., & Zahara, W. (2024). Analisis faktor pengulangan radiograf (repeat) di instalasi radiologi Rumah Sakit Umum Daerah Padang Pariaman. Jurnal Kesehatan Medika Saintika, 15(2), 234–242. https://doi.org/10.30633/jkms.v15i2.2801
Menteri Kesehatan Republik Indonesia. (2008). Keputusan Menteri Kesehatan Republik Indonesia Nomor: 129/Menkes/SK/II/2008. https://www.bertelsmannstiftung.de/fileadmin/files/BSt/Publikationen/GrauePublikationen/MT_Globalization_Report_2018.pdf
Papp, J. (2018). Quality management in the imaging sciences e-book. Elsevier Health Sciences.
Peraturan Menteri Kesehatan Republik Indonesia. (2020). Peraturan Menteri Kesehatan Republik Indonesia Nomor 24 Tahun 2020 tentang.
Pratama, R. (2021). Studi literatur pada repeat film analysis di instalasi radiologi. Naskah Publikasi.
Wahyuddin, W., Iskandar, A. R., & Adilah Z., N. (2021). Analisa artefak pada hasil radiograf yang timbul akibat pengolahan computed radiography. Lontara, 2(1), 31–34. https://doi.org/10.53861/lontarariset.v2i1.186
Yoshandi, T. M., Sayuti, A., & Bisra, M. (2020). Analisa pengulangan (repeat) citra radiografi di unit radiologi Rumah Sakit Awal Bros Panam Pekanbaru. Journal of Hospital Administration and Management, 1(2), 11–14. https://doi.org/10.54973/jham.v1i2.55
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Jurnal Ilmiah Kedokteran dan Kesehatan

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.