Analysis of the Influence of Residential Electrical Installation Errors on Prepaid Kwh Meter Errors in the PT PLN (Persero) ULP Stabat Area
DOI:
https://doi.org/10.55606/jeei.v5i2.4148Keywords:
Grounding, Installation, Leakage Current, TemperingAbstract
There are several things that happen when customers use electricity with prepaid Kwh meters. One of the problems now is an error in the Kwh meter or commonly called Kwh tempering. This study uses an observation method by taking a sample of 2 houses that have tempering problems in their Kwh. The results of the study of the first house with 900 VA electricity power found a current leak of 0.3 A, and in the second house with 1300 VA electricity power found a grounding cable connected to the neutral cable which caused a limping load of 0.85 A.
References
Akbara, R. (2021). Analysis of the influence of abnormal conditions due to wiring errors in customer electrical installations on power measurements on prepaid KWH meters of PT PLN customers (Undergraduate thesis, Mercu Buana University, Jakarta).
Aminullah, M. W., Yulita, D., Arbi, H., & Anggara, D. R. (2022). The effect of grounding use on prepaid KWH meters. Tesla, 24(1), 1–12. https://doi.org/10.24912/tesla.v24i1.13265
Anisah, S., & Tarigan, A. D. (n.d.). Effectiveness of utilizing energy saving lights in community living houses.
Anisah, S., Tharo, Z., & Suhardi, S. (2019). Analysis of end voltage improvement in 20 kV medium voltage networks with E-TAP simulation (Case study of PT PLN (Persero) Rayon Kuala). In Proceedings of the UISU National Engineering Seminar (SEMNASTEK).
Aryza, S., Irwanto, M., Lubis, Z., Siahaan, A. P. U., Rahim, R., & Furqan, M. (n.d.). A novelty design of minimization of electrical losses in a vector controlled induction machine drive. IOP Conference Series: Materials Science and Engineering.
Harahap, P. A., Tharo, Z., & Tarigan, A. D. (2019). Comparative analysis of grounding systems in power houses and office buildings. Collection of Scientific Works of Students of the Faculty of Science and Technology.
Mustafa, F., Karnoto, K., & Winardi, B. (2018). Analysis of the effect of tampering conditions due to wiring errors in customer-owned electrical installations on power measurements on digital prepaid KWH meters of PT PLN customers. Transient: Jurnal Ilmiah Teknik Elektro, 7(2), 486–493.
Putra, I. W. S. (2024). Identification of 1 phase digital KWH meter disturbances for customers at PT. PLN (Persero) ULP Denpasar (Diploma thesis, Bali State Polytechnic).
Rahmaniar, R., Syahputra, M. R., Lesmana, D., & Junaidi, A. (2022). Socialization of understanding the dangers of touch voltage and short circuits in electrical systems for village communities in Kota Pari. Journal of Community Service, 3(2).
Santoso, A., Rasmini, N. W., & Ta, I. K. (2022). Analysis of KWH meter check due to leakage current in customer installations (Diploma thesis, Bali State Polytechnic).
Siagian, R. P., Dalimunthe, M. E., & Siagian, P. (2024). Performance analysis of modification of single phase measuring and limiting devices in customers which causes non-technical losses in PT. PLN ULP Meulaboh. JITET (Journal of Informatics and Applied Electrical Engineering), 12(3).
Tharo, Z., Kusuma, B. S., Anisah, S., & Dhalimunte, M. E. (2021). Comparative analysis of prepaid and postpaid KWH meter performance. In 2021 National Conference on Social and Engineering, Medan State Polytechnic.